30 Hp 3 Phase Motor

30 Hp 3 Phase Motor

This 30 HP three-phase motor is designed for high performance and reliability in industrial applications. Its rugged construction allows for continuous operation in demanding environments and is suitable for heavy-duty equipment such as pumps, compressors and conveyors. The motor is enclosed to prevent dust and moisture ingress, extending its service life. Its smooth starting performance and low vibration ensure safe and efficient operation.
Send Inquiry
30 hp 3 phase motor

High-efficiency design: The motor uses advanced electromagnetic design to significantly improve the energy efficiency level. This design can minimize power loss and keep the motor efficient during operation. Compliance with international energy efficiency standards means that it not only meets current energy conservation requirements, but also remains competitive in future energy conservation regulations. Long-term use of this motor can significantly reduce power consumption and help companies reduce operating costs, especially in large-scale use scenarios.

Rugged and durable: The motor housing is made of high-strength cast iron material with excellent impact and corrosion resistance. This material can provide long-term protection in harsh industrial environments and is suitable for a variety of industrial applications such as pumps, fans, compressors and conveyors. Whether it is a hot, humid or dusty environment, the motor can operate stably, reducing the risk of failure caused by external environmental factors, thereby extending the service life of the equipment.

Enclosed design: The motor adopts a fully enclosed fan cooling (TEFC) structure, which can effectively prevent dust, dirt and moisture from entering the interior and protect the key components of the motor from the outside environment. This design not only extends the service life of the motor, but also reduces the maintenance requirements caused by environmental pollution. Less maintenance means less downtime, which improves overall production efficiency and equipment availability.

Low vibration and low noise: The motor is precisely balanced, with minimal vibration and noise during operation. This is especially important for applications with high operating environment requirements, such as air conditioning systems, ventilation equipment, and equipment in office environments. The low vibration and low noise design not only improves the operator's working comfort, but also reduces the potential loss of equipment due to vibration, and extends the service life of the motor and connected equipment.

Excellent starting performance: The motor has a high starting torque and can easily cope with various heavy-load starting requirements. In operations with frequent starts and stops, such as production lines and material handling systems, the reliable starting performance of the motor ensures smooth startup and stable operation of the equipment. Even under heavy loads, the motor can maintain efficient operation to avoid production delays caused by difficult starting.

30 hp 3 phase motor
30 hp 3 phase motor

 

30 hp 3 phase motor

 

 

Technical specifications
 

 

Parameter Specification
Power Rating 30 HP
Voltage 230/460 V
Frequency 60 Hz
Current 72/36 A
Speed (RPM) 1750 RPM
Efficiency 93.6%
Power Factor 0.87
Frame Size 286T
Insulation Class F
Enclosure Type Totally Enclosed Fan Cooled (TEFC)
Service Factor 1.15
Mounting Type Foot-mounted (Horizontal)
Bearing Type Ball Bearings
Ambient Temperature -20°C to 40°C
Protection Class IP55
Weight 350 lbs (approx.)
Thermal Protection Built-in thermal overload protection
Rotation Counterclockwise (CCW)
Duty Type Continuous (S1)

 

 

 

Application areas of 30 hp 3 phase motor
 
Industrial Pump Applications in Miami - Miami Pump & Supply

Pump applications: This motor plays a vital role in water treatment facilities, agricultural irrigation systems, and industrial fluid transportation. It is usually used to drive various types of pumps, such as centrifugal pumps, sewage pumps, and booster pumps. In water treatment facilities, the motor provides stable and strong power output for the pump, ensuring efficient extraction of raw water, transportation of purified water, and treatment and discharge of wastewater. Its high-efficiency design enables the pump to operate efficiently under various operating conditions, thereby optimizing the entire water treatment process. In agricultural irrigation systems, motor-driven pumps can adapt to different flow and pressure requirements to ensure a stable supply of irrigation water, whether in field irrigation or horticultural irrigation, it can meet the requirements of efficient irrigation. In addition, in industrial fluid transportation, the motor also performs well. Whether it is the transportation of chemical liquids or the circulation of cooling water in the production process, it can ensure the continuous and stable transmission of fluids, reduce system failures caused by flow fluctuations or insufficient pressure, and thus improve production efficiency.

Fans and blowers: This motor is widely used in ventilation, air-conditioning systems and industrial exhaust devices, and has become the core driving equipment in these systems. Especially in factories, warehouses and commercial buildings, fans and blowers driven by this motor can ensure effective air circulation and maintain the comfort and safety of the indoor environment. In air conditioning systems, the motor provides continuous and stable power output for the fan to ensure that cold or hot air is evenly distributed indoors, thereby achieving good temperature control and air quality. In industrial exhaust devices, blowers driven by this motor can efficiently exhaust harmful gases, dust and smoke generated during the production process, maintain clean air in the workshop, and protect the health of workers and production safety. Due to the characteristics of low vibration and low noise, when the motor is used in ventilation systems, it not only improves the operating efficiency of the equipment, but also reduces noise pollution, which is particularly suitable for environments with strict noise requirements. In addition, the motor's sturdy structure and protection level enable it to work stably in dusty or humid environments, further extending the service life of the equipment, reducing maintenance requirements, and improving the overall reliability of the system.

Centrifugal Fans/Blowers

 

 

Installation Method:
 

 

Structure and installation type
(IM code))
IM B3 IM B8 IM B5 IM B6 IM V5 IM V1 IM B7 IM V6 IM V3
Installation diagram productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400
Frame size 63-450 63-160 63-280 63-160 63-160 63-450 63-160 63-160 63-160
Structure and installation type
(IM code))
IM V37 IM V17 IM B34 IM V19 IM V18 IM B14 IM V35 IM V15 IM B35
Installation diagram productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400 productcate-400-400
Frame size 63-132 63-13 63-132 63-132 63-132 63-132 63-160 63-160 63-450

 

 

 

 

 

 

 
FAQ

1: How efficient is the motor, and how much does it affect our energy consumption?
The motor has an efficiency of 93.6%, which means that during normal operation, only about 6.4% of the electrical energy is converted into heat or other forms of energy loss. This high-efficiency design can significantly reduce energy consumption, especially when it is running continuously for a long time, the electricity cost savings will be considerable. This is an important advantage for companies seeking to reduce operating costs.
2: How is the starting performance of the motor, and can it cope with the starting requirements of heavy-duty equipment?
The motor has a high starting torque and can easily cope with the starting requirements of heavy-duty equipment. Whether it is a compressor, pump or conveyor system, the motor can start smoothly under heavy load conditions to avoid starting difficulties or equipment damage. This is especially important for production lines that need to be started frequently to ensure stable operation of the equipment.
3: How is the running noise of the motor, and is it suitable for noise-sensitive environments?
The motor has been finely balanced and has very low noise during operation. This makes the motor very suitable for installation in environments with strict noise requirements, such as commercial buildings, office areas or residential areas. Low noise not only improves the comfort of the working environment, but also reduces the impact of noise pollution on employees and the surrounding environment.
4: How durable is the motor and what are the maintenance requirements?
The motor features a high-strength cast iron housing and a fully enclosed fan-cooled (TEFC) structure, which provides excellent durability. It is able to operate stably for long periods of time in harsh industrial environments, and is designed with reduced maintenance requirements in mind. Less frequent maintenance means longer uptime and lower operating costs, which is particularly critical for companies with high production continuity requirements.
5: Is the motor suitable for use in dusty or humid environments?
Yes, the motor's enclosed design and IP55 protection rating enable it to operate safely in dusty or humid environments. The TEFC structure prevents dust and moisture from entering the motor, thereby protecting key components and extending the life of the equipment. This makes the motor suitable for harsh environments such as mining, chemicals, and food processing.
6: Is the motor easy to install?
The motor is designed to be flexible and supports a variety of mounting methods, including base mounting and flange mounting. Its terminal box adopts a swivel design, which makes electrical connections more convenient, further improving the ease of installation. Whether it is a new equipment installation or an old equipment replacement, the motor can be quickly and easily integrated into an existing system.
7: How safe is the motor, and are there any built-in protection measures?
The motor is equipped with a built-in thermal protection device. When the motor temperature exceeds the safe range, the device will automatically cut off the power supply to prevent damage caused by overheating. This function greatly improves the safety of the equipment, especially in the case of overload or voltage fluctuations, and can effectively protect the motor and related equipment.

 

Hot Tags: 30 hp 3 phase motor, China 30 hp 3 phase motor manufacturers, suppliers, factory, synchronous machine, dc pm motor, gear box with motor, ac motor, standard motors, synchronous motor

Send Inquiry